Hotel room

Includes hotel room wall cases of IGOODS by AIGUOSI. The page focuses on the core constraints of the room - most partition walls are lightweight and do not have hanging conditions, so the weight of the material becomes the first threshold (flexible stone about 3-7kg/㎡, full adhesion is enough). And give verifiable control points: the flatness of the base layer is ≤3mm when measured with a 2m ruler, the small radius of the headboard arc must be tried with a template first, the flammability is graded according to GB 8624-2012, and the indoor environmental pollution of the room is controlled according to the I class civil building limit value of GB 50325-2020.

The following cases come from actual engineering projects of IGOODS, which can be cross-referenced with product details and material selection guides.

Cases implemented
14each
Covered city
10each
Involved part
headboard wall, light-weight partition wall, external wall of wet area
Check items on this page
6Item ·7Item basis

Case index

The table lists the cases of this type by project, city, main materials and construction area, which is convenient for quick positioning by scale and material. The case detail page contains complete material selection basis and construction records.

CaseCityMain material.Construction area
Bamboo weaved soft stone hotel room close-up case———
Cherry wood grain - flexible stone - hotel room 1———
industrial wind power competition hotel-cement casting board-soft stone———
print slab stone - embroidery red - soft stonePanzhihua Cityprint slab stone (embroidery red1640 square meters
Sunset Golden Mountain - golden - hotel guest room wall decoration material recommendation———
hotel-printed slab stone wu ling white silkZhaotong Cityslab stone (wu ling white silk (black and white1560 square meters
Hotel wall decoration material-Soft Stone Star Moon Stone-Flexible StoneDali CityStar Moon Stone (Light Beige)2240 square meters
Hotel room-Flexible Stone-Milky Yellow Wood GrainYuxi CityWood Grain (Moss Green Wood Grain1720 square meters
Hotel room-Jute Soft StonePu'er CityBamboo weaved soft stone (Beige1680 square meters
Recommended wall materials for hotel guest roomsKunming CityRattan soft stone (gray green)1860 square meters
Hotel guest room cherry wood grain stoneLijiang CityWood grain (cherry wood)1580 square meters
Hotel room decoration effect diagram - flexible stone - bamboo weaving soft stoneQujing CityBamboo weaving soft stone (milky white1760 square meters
Hotel printed slateLincang CitySlate (moss green plant pattern1320 square meters
High-end hotel - flexible stone - printed slate embroidery redTongren CitySlate (Brocade1240 sqm

When viewing these cases, it is recommended to check these 6 items.

Every item comes from a place where a problem has occurred in an actual project. The order of checking is also very important - the judgment of the base and shape comes first, followed by the color.

  • The partition walls of the guest room are mostly light-quality walls and do not have hanging conditions.
    The partition walls between rooms are usually made of light-weight bricks or light steel stud walls. The weight of the material is a strict constraint, which is also the reason why hotel rooms rarely use natural stone as the background wall.
  • The headboard wall faces the guest's line of sight and is the visual core of the guest room
    What the guest faces when lying down is the headboard background wall. The area is not large, and it is more suitable to use textured materials for a highlight instead of relying on shaping and piling up.
  • The corner and curved surface of the headboard shape
    The sides of the headboard are often wrapped in a shaping, and if the curved corner is used to paste pieces of hard material, the seam will fall exactly at the height of the line of sight. Bending the whole piece over is cleaner.
  • The outer wall of the bathroom is always humid
    The outer wall of the bathroom in the guest room is always in a humid environment, and the premise is that the material does not absorb water or swell. The dry area can be directly pasted, and the range of the wet area is determined according to the dry and wet zoning map.
  • The coordination of room lighting color temperature and material
    The room mainly uses warm light of 2700-3000K. The same color tone is thicker under warm light and gray under cold light. The color selection must be compared under actual lighting.
  • Cleaning and maintenance should be suitable for the daily operations of the room department
    The tools and processes of the room department are fixed, the wall material must be able to be cleaned with existing tools and neutral cleaning agents, the surface must be dense and no fingerprints.

Key indicators and acceptance criteria

The table lists the indicators, reference values and basis that can be checked for the type of this project.★Project experienceIt indicates the range of common practices in the industry and is not used as a reference for national standard data; those with standard numbers can be directly verified.

ProjectReference value / PracticeBased on
Substrate flatness2m Rule inspection, gaps ≤3mm★Engineering Experience; Can be compared with GB 50210-2018 for allowable deviation in the installation of decorative panels
The suitability of light-weight partition wallsFull adhesive construction method, no need to pre-bury steel frame★Engineering experience; the base strength and flatness must be inspected and qualified first
Self-weight per square meter of materialFlexible stone about 3-7 kg/㎡, light-weight partition walls can withstandOn-site product archives (by model)
Headboard curved surfaceUse a physical sample to try bending with a small radius first, and narrow strip splicing if the rebound is obvious★Project experience
Combustion performanceGraded according to GB 8624-2012, the detection report of the selected model is taken as the standard.GB 8624-2012 Classification of Combustion Performance of Building Materials and Products
Sound insulationSound insulation requirements for guest room partition walls must be executed according to the sound insulation design specifications for civil buildingsGB 50118-2010 Design Code for Sound Insulation of Civil Buildings
Indoor environmental pollutionGuest room control according to the I class civil building limit valueGB 50325-2020 Indoor Environmental Pollution Control Standard for Civil Engineering Construction

Common questions (FAQ) of hotel guest rooms

The following are the most frequently asked questions in the design and procurement stages of this type of project

Can the guest room partition wall be pasted? Will it damage the wall?

Yes. The self-weight per square meter of flexible stone is about 3-7kg/㎡, and lightweight block walls and light steel frame walls can be fully adhered after leveling, without the need for pre-embedded steel frames. The premise is that the substrate has passed acceptance.

How to do the arched corner of the headboard wall?

Bend the whole piece over. If the arched corner is pasted in pieces, the seam will fall exactly at the height of the guest's line of sight when lying down. For small radii, it is recommended to try bending with a physical sample first.

Will the color of the guest room change under warm light?

Yes. Under warm light, the color is rich and thick, and under cold light, it is gray. It is necessary to see the actual samples under the actual lighting of the guest room, and the exhibition hall and screen are not counted.

Will the wall outside the bathroom get damp?

The material itself does not absorb water, and can be directly pasted in the dry area. The range of the wet area should be confirmed in combination with the dry-wet zoning map, and waterproofing should still be done first in the wet area.

How to clean the guest room wall daily?

Neutral cleaner with soft cloth. Dense surface materials will not leave fingerprints and can significantly reduce the amount of work needed in the guest room department.

What kind of inspection reports are needed for the guest room project?

Standard requires combustion performance (GB 8624-2012 classification), formaldehyde and VOC report, chain hotel brands usually have their own material access standards.

Related pages and requests

Overview of hotel and inn cases·Hotel lobby case·Hotel corridor case·wood paneling wall·Selection Guide

Diameter specification:The indicators listed on this page include★Project experienceThis is a common practice range in the industry, used for estimation and self-check, not as a national standard data reference; those with standard numbers are standard files that can be verified. Material parameters are confirmed according to product archives and orders, and combustion performance and environmental grade are based on the effective inspection report of the selected model.

Contact phone number Product Catalog Free Sample
WeChat ID copied